• 5.4 cm bore
• Operation field at 11.7 Tesla
• Ascend design for very significant reduction of the stray field
• Advanced External Disturbance Suppression (EDS™) for dramatic reduction
of magnetic field perturbations
• Bruker Smart Magnet System (BSMS™) shim and Digital Lock™ control,
including Digital Frequency Generation, Digital Quadrature Receiver, computer-controlled
lock regulation system and ultra-stable, low current noise Shim Control Boards (SCBs)
• Bruker Orthogonal Shim System (BOSS™-3) with 36 low current and low heat
dissipation gradient shims
• BST (Bruker Sample Transport) upper shim stack. Enables high flow rates
for VT gas and includes integral sensors for communication with the BSMS
• Signal Generation Unit for 4 channels,
for generation of phase, amplitude, and frequency using Direct Digital
Synthesis
• Gradient Controller for simultaneous control of up to three magnetic field
gradients with real time generation of gradient shapes
• Digital Receiver Unit (DRU™) with integrated high performance digital
filters and Digital Quadrature Detection (DQD™)
• Second Generation Digital Quadrature Detection Receiver (2G-DR) with
integrated high performance ADCs
• BLAXH2H300/100/150 transmitter system
• BH2078 BLAX500 linear broadband amplifier for X-nucleus pulse and
decouple with ultra-fast blanking and rise/fall times
• Convenient sample access at desk height
• Safe operation on the side of the magnet
• 24 easily accessed sample positions
• Random access for sequential- or batch automation
• Unique manual push-button sample exchange
• Supports all common sample-tubes in spinners or shuttles
• 1H preamplifier
• 2D preamplifier (for lock and 2D observe)
• BB preamplifier
• Control unit
• Built-in tune/match display
• Inverse triple resonance (TXI) probe (5 mm sample diameter) for observation of 1H while decoupling 13C and 15N, including 2D lock.
• Multinuclear Broadband Fluorine Observe SmartPROBE™ (5 mm
sample diameter) with digital tuning covering the range from 15N to 31P
as well as 19F with 1H decoupling.
• GRASP™ II version, including actively shielded Z-gradient coil for use with GRASP™ II or GRASP™ II/A accessory.
• VT range -150°C to +150°C
• Automatic Tuning and Matching Accessory
• Pre-cooling and stabilization accessory
• For ultra-precise temperature control from near ambient conditions down to 0°C sample temperature.
• Low temperature accessory for BVT Variable Temperature control unit
• 26 liter N2 dewar, heat evaporator and stainless steel transfer
line for operation down to -120°C
• Intel Dual Core™ 2.53GHz Processor
• 4 GB memory
• 19 inch Flat Panel monitor
• 500GB Hard Drive
• 16X max DVD±RW/CD-RW drive
• 2 X LAN 10/100/1000 ethernet adapters
• Microsoft Windows 7 Professional